Bare Cooper Conductor Cable Wire

Product Details
Customization: Available
Type: Bare
Conductor Type: Solid
Still deciding? Get samples of $ !
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (27)
  • Bare Cooper Conductor Cable Wire
  • Bare Cooper Conductor Cable Wire
  • Bare Cooper Conductor Cable Wire
  • Bare Cooper Conductor Cable Wire
  • Bare Cooper Conductor Cable Wire
  • Bare Cooper Conductor Cable Wire
Find Similar Products

Basic Info.

Model NO.
Bare Cooper Conductor Cable
Application
Overhead
Conductor Material
Copper
Sheath Material
No
Insulation Material
No
Material Shape
Round Wire
Range of Application
Laying Room
Certification
ISO9001, CCC
Brand
Dongchao
Number of Cores
1
Rated Voltage
0.6/1kv 1~35kv
Length
Lengths Customize
Insulation
None
Transport Package
Roll/Wooden Drum
Origin
China
Production Capacity
5000000m/Month

Product Description

 

Ectrical conductivity:
  Electrical conductivity is a measure of how well a material transports an electric charge. This is an essential property in electrical wiring systems. Copper has the highest electrical conductivity rating of all non-precious metals: the electrical resistivity of copper = 16.78 nΩ•m at 20 °C.
  The theory of metals in their solid state] helps to explain the unusually high electrical conductivity of copper. In a copper atom, the outermost 4s energy zone, or conduction band, is only half filled, so many electrons are able to carry electric current. When an electric field is applied to a copper wire, the conduction of electrons accelerates towards the electropositive end, thereby creating a current. These electrons encounter resistance to their passage by colliding with impurity atoms, vacancies, lattice ions, and imperfections. The average distance travelled between collisions, defined as the mean free path, is inversely proportional to the resistivity of the metal. What is unique about copper is its long mean free path (approximately 100 atomic spacings at room temperature). This mean free path increases rapidly as copper is chilled. Because of its superior conductivity, annealed copper became the international standard to which all other electrical conductors are compared. In 1913, the International Electrotechnical Commission defined the conductivity of commercially pure copper in its International Annealed Copper Standard, as 100% IACS = 58.0 MS/m at 20 °C, decreasing by 0.393%/°C. Because commercial purity has improved over the last century, copper conductors used in building wire often slightly exceed the 100% IACS standard.
  The main grade of copper used for electrical applications is electrolytic-tough pitch (ETP) copper (CW004A or ASTM designation C11040). This copper is at least 99.90% pure and has an electrical conductivity of at least 101% IACS. ETP copper contains a small percentage of oxygen (0.02 to 0.04%). If high conductivity copper needs to be welded or brazed or used in a reducing atmosphere, then specially-pure oxygen-free copper (CW008A or ASTM designation C10100) may be used; it is about 1% more conductive (i.e., achieves a minimum of 101% IACS).
  Several electrically conductive metals are less dense than copper, but require larger cross sections to carry the same current and may not be usable when limited space is a major requirement. Aluminium has 61% of the conductivity of copper. The cross sectional area of an aluminium conductor must be 56% larger than copper for the same current carrying capability. The need to increase the thickness of aluminium wire restricts its use in many applications.such as in small motors and automobiles. However, in some applications such as aerial electric power transmission cables, aluminium predominates, and copper is rarely used.Silver, a precious metal, is the only metal with a higher electrical conductivity than copper. The electrical conductivity of silver is 106% of that of annealed copper on the IACS scale, and the electrical resistivity of silver = 15.9 nΩ•m at 20 °C. The high cost of silver combined with its low tensile strength limits its use to special applications, such as joint plating and sliding contact surfaces, and plating for the conductors in high-quality coaxial cables used at frequencies above 30 MHz.

Tensile strength:
  Tensile strength measures the force required to pull an object such as rope, wire, or a structural beam to the point where it breaks. The tensile strength of a material is the maximum amount of tensile stress it can take before breaking.
Copper's higher tensile strength (200-250 N/mm2 annealed) compared to aluminium (100 N/mm2 for typical conductor alloys[) is another reason why copper is used extensively in the building industry. Copper's high strength resists stretching, neck-down, creep, nicks and breaks, and thereby also prevents failures and service interruptions.]Copper is much heavier than aluminum for conductors of equal current carrying capacity, so the high tensile strength is offset by its increased weight.

Ductility:
  Ductility is a material's ability to deform under tensile stress. This is often characterized by the material's ability to be stretched into a wire. Ductility is especially important in metalworking because materials that crack or break under stress cannot be hammered, rolled, or drawn (drawing is a process that uses tensile forces to stretch metal).
  Copper has a higher ductility than alternate metal conductors with the exception of gold and silver. Because of copper's high ductility, it is easy to draw down to diameters with very close tolerances.

Strength and ductility combination:
  Usually, the stronger a metal is, the less pliable it is. This is not the case with copper. A unique combination of high strength and high ductility makes copper ideal for wiring systems. At junction boxes and at terminations, for example, copper can be bent, twisted, and pulled without stretching or breaking.

Creep resistance:
  Creep is the gradual deformation of a material from constant expansions and contractions under varying load conditions. This process has adverse effects on electrical systems: terminations can become loose, causing connections to heat up or create dangerous arcing.
  Copper has excellent creep characteristics that minimizes loosening at connections. For other metal conductors that creep, extra maintenance is required to check terminals periodically and ensure that screws remain tightened to prevent arcing and overheating.

Corrosion resistance:
  Corrosion is the unwanted breakdown and weakening of a material due to chemical reactions. Copper generally resists corrosion from moisture, humidity, industrial pollution, and other atmospheric influences. However, any corrosion oxides, chlorides, and sulfides that do form on copper are somewhat conductive. Under many application conditions copper is higher on the galvanic series than other common structural metals, meaning that copper wire is less likely to be corroded in wet conditions. However, any more anodic metals in contact with copper will be corroded since they will essentially be sacrificed to the copper.

Coefficient of thermal expansion:
  Metals and other solid materials expand upon heating and contract upon cooling. This is an undesirable occurrence in electrical systems. Copper has a low coefficient of thermal expansion for an electrical conducting material. Aluminium, an alternate common conductor, expands nearly one third more than copper under increasing temperatures. This higher degree of expansion, along with aluminium's lower ductility, can cause electrical problems when bolted connections are improperly installed. By using proper hardware, such as spring pressure connections and cupped or split washers at the joint, it may be possible to create aluminium joints that compare in quality to copper joints.

Thermal conductivity:
  Thermal conductivity is the ability of a material to conduct heat. In electrical systems, high thermal conductivity is important for dissipating waste heat, particularly at terminations and connections. Copper has a 60% higher thermal conductivity rating than aluminium, so it is better able to reduce thermal hot spots in electrical wiring systems.

Solderability:
  Soldering is a process whereby two or more metals are joined together by a heating process using a filler material that has a much lower melting point than the metal to be joined. This is a desirable property in electrical systems. Copper is readily soldered to make durable connections when necessary.

Ease of installation:
  The strength, hardness, and flexibility of copper make it very easy to work with. Copper wiring can be installed simply and easily with no special tools, washers, pigtails, or joint compounds. Its flexibility makes it easy to join, while its hardness helps keep connections securely in place. It has good strength for pulling wire through tight places, including conduits. It can be bent or twisted easily without breaking. It can be stripped and terminated during installation or service with far less danger of nicks or breaks. And it can be connected without the use of special lugs and fittings. The combination of all of these factors makes it easy for electricians to insta copper wire.

Solid and stranded:
  Solid wire consists of one strand of copper metal wire, bare or surrounded by an insulator. Single-strand copper conductors are typically used as magnet wire in motors and transformers. They are relatively rigid, do not bend easily, and are typically installed in permanent, infrequently handled, and low flex applications.
Stranded wire has a group of copper wires braided or twisted together. Stranded wire is more flexible and easier to install than a large single-strand wire of the same cross section. Stranding improves wire life in applications with vibration. A particular cross-section of a stranded conductor gives it essentially the same resistance characteristics as a single-strand conductor, but with added flexibility

Applications:
  Electrolytic-tough pitch (ETP) copper, a high-purity copper that contains oxygen as an alloying agent, represents the bulk of electrical conductor applications because of its high electrical conductivity and improved annealability. ETP copper is used for power transmission, power distribution, and telecommunications.  Common applications include building wire, motor windings, electrical cables, and busbars. Oxygen-free coppers are used to resist hydrogen embrittlement when extensive amounts of cold work is needed, and for applications requiring higher ductility (e.g. telecommunications cable). When hydrogen embrittlement is a concern and low electrical resistivity is not required, phosphorus may be added to copper.
For certain applications, copper alloy conductors are preferred instead of pure copper, especially when higher strengths or improved abrasion and corrosion resistance properties are required. However, relative to pure copper, the higher strength and corrosion resistance benefits that are offered by copper alloys are offset by their lower electrical conductivities. Design engineers weigh the advantages and disadvantages of the various types of copper and copper alloy conductors when determining which type to specify for a specific electrical application. An example of a copper alloy conductor is cadmium copper wire, which is used for railroad electrification in North America. In Britain the BPO (later Post Office Telecommunications) used cadmium copper aerial lines with 1% cadmium for extra strength; for local lines 40 lb/mile (1.3 mm dia) and for toll lines 70 lb/mile (1.7 mm dia). Some of the major application markets for copper conductors are summarized below.

SPECIFICATIONS:
ASTM B-1 Hard Drawn Temper
ASTM B-2 Medium Hard Drawn TemperASTM B-3 5oft Drawn Temper

STRANDED:
ASTM B-1 Hard Drawn Temper
ASTM B-2 Medium Hard Drawn Temper
ASTM B-3 soft Drawn Temper
ASTM B-8-concentric Lay,All Tempers

Structure size and technology data :