Low Friction UL Type Thhn/Thwn-2 Copper Conductor Cable Wire

Product Details
Customization: Available
Type: Bare
Conductor Type: Solid
Still deciding? Get samples of $ !
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (27)
  • Low Friction UL Type Thhn/Thwn-2 Copper Conductor Cable Wire
  • Low Friction UL Type Thhn/Thwn-2 Copper Conductor Cable Wire
  • Low Friction UL Type Thhn/Thwn-2 Copper Conductor Cable Wire
  • Low Friction UL Type Thhn/Thwn-2 Copper Conductor Cable Wire
  • Low Friction UL Type Thhn/Thwn-2 Copper Conductor Cable Wire
  • Low Friction UL Type Thhn/Thwn-2 Copper Conductor Cable Wire
Find Similar Products

Basic Info.

Model NO.
Low Friction UL Type THHN/THWN-2 Copper Conductor
Application
Heating
Conductor Material
Copper
Sheath Material
PVC
Insulation Material
XLPE
Material Shape
Round Wire
Range of Application
Mine
Certification
ISO9001, CE
Brand
Dongchao
Rated Voltage
600V
Number of Cores
1
Color
Black or Orthers
Packing
Roll/Wooden Drum
Standards
ASTM B3/B8 UL 83
Temperature
9o′c Dry or Wet
Transport Package
Cartons, Wooden Wheels, Soft
Specification
14AWG to 1000AWG
Origin
China
HS Code
8544492100
Production Capacity
500km/Month

Product Description

Low Friction UL Type THHN/THWN-2 Copper Conductor cable

Product Construction:
Conductor: • 14 AWG thru 750 kcmil bare annealed stranded copper per ASTM B3 and ASTM B8 • 14 AWG thru 10 AWG solid plain copper per ASTM B3

Insulation:
 Color-coded premium-grade flame-retardant, heat- and moisture-resistant Polyvinyl Chloride (PVC)

Jacket:Tough Polyamide (Nylon)

Print:
For 14 AWG solid thru 10 AWG solid:
• GENERAL CABLE® (PLANT OF MFG) (YEAR OF MFG) THHN/THWN (SIZE) AWG (SIZE mm²) GAS AND OIL RES II 600V VW-1 (UL) E66903 C(UL) T90 NYLON/TWN75 FT1 (-25°C)
For 14 AWG strand thru 10 AWG strand:
• GENERAL CABLE® (PLANT OF MFG) (YEAR OF MFG) THHN/THWN (SIZE) AWG (SIZE mm²) GAS AND OIL RES II 600V VW-1 OR AWM (UL) E66903 C(UL) T90 NYLON/TWN75 FT1 (-25°C)
For 8 AWG thru 1 AWG:
• GENERAL CABLE® (PLANT OF MFG) (YEAR OF MFG) LOW FRICTION THHN/THWN-2 (SIZE) AWG (SIZE mm²) GAS AND OIL RES II 600V VW-1 OR AWM (UL) E66903 C(UL) T90 NYLON/TWN75 FT1 (-25°C)
For 1/0 and larger, black only:
• GENERAL CABLE® (PLANT OF MFG) (YEAR OF MFG) LOW FRICTION THHN/THWN-2 (SIZE) AWG (SIZE mm²) GAS AND OIL RES II OR SUN RES FOR CT USE 600V OR AWM (UL) E66903 C(UL) T90 NYLON/TWN75 FT1 (-25°C)

Print (cont'd.):
For 1/0 and larger, all colors:
• GENERAL CABLE® (PLANT OF MFG) (YEAR OF MFG) LOW FRICTION THHN/THWN-2 (SIZE) AWG (SIZE mm²) CU GAS AND OIL RES II FOR CT USE 600V OR AWM (UL) E66903 C(UL) T90 NYLON/TWN75 FT1 (-25°C)

Applications:
Copper THHN/THWN-2 conductors are primarily used in conduit and cable trays, when approved, for servicesfeeders and branch circuits in commercial or industrial applications as specified in the National Electric Code.THHN applications are suitable for use in dry locations only at temperatures not to exceed 90°C. THWN-2applications are suitable for use in either wet or dry applications, with temperatures that do not exceed 90'c
• General purpose building wire for services, feeders and branch circuits
• Conduit and raceways
• 1/0 and larger for cable tray use

Features:
• Low Friction Nylon jacket provides easy pulling for 8 AWG and larger
• 1/0 AWG and larger are rated for cable tray use
• Rated Gasoline and Oil-Resistant II
• Resistant to abrasion, acids, alkalines, ozone, and water
• For THHN applications, the conductor is appropriate for use in dry locations not to exceed 90°C
• For THWN-2 applications, the conductor is appropriate for wet or dry locations not to exceed 90°C

Features (cont'd.):
•For MTW applications, the conductor is appropriate for use in dry locations at 90°C or not to exceed 60°C in wet locations or where exposed to oil or coolants (with ampacity limited to that for 75°C conductor temperature) as outlined in NFPA79 Electrical •Standards for Industrial Machinery
•Sequential foot markings every 2 feet on 8 AWG and larger for easy measuring
•Sunlight-resistant for 1/0 and larger, for black only
•Meets cold bend and cold impact tests at -25°C

Compliances:
•Industry Compliances:
•ASTM B3 and B8 • UL Standard 83 - THHN/THWN-2
•UL Standard 1063 for machine tool wire (MTW)
•ICEA S-95-658/NEMA WC70 • NEC® Article 310 • RoHS Compliant
•c(UL) - T90 Nylon Flame Test Compliances:
•UL 2556 VW-1 rated through 1 AWG
•UL 2556 CT USE 1/0 and larger Packaging:
•Cut-to-length services available for 8 AWG and larger


Structure size and technology data :